Hi There,
While running a parallel MD simulation, I got following message while
playing with parameters:
NOTE 3 [file aminoacids.dat, line 1]:
  The optimal PME mesh load for parallel simulations is below 0.5
  and for highly parallel simulations between 0.25 and 0.33,
  for higher performance, increase the cut-off and the PME grid spacing
---------------------------

I don't have any idea when a run should be called a highly parallel
simulation?
Is it depend on problem-size or the number of processor we are using?

I am trying to optimize my simulation to run on 224 processors and system
consist of:

Total atom count = 54640
where water molecules = 17074

Also, I am getting following message while running grompp
---------------------------------
NOTE 1 [file md.mdp, line unknown]:
  The Berendsen thermostat does not generate the correct kinetic energy
  distribution. You might want to consider using the V-rescale thermostat.
------------------------------------
Any insight in the above message will be highly appreciated.

Please advice me how to optimize the parameters to run the simulation with
maximum efficiency.

With thanks in advance,
Vivek
_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to