Enemark Soeren wrote:
Ahh, now I understand - sorry, Omer!

In fact, I have compared all three single hydrogen RDFs and they are identical and also relatively smooth. Since, however, with 3 times more data points (all three hydrogen atoms taken together) I get a different RDF, would that indicate that I do not have enough data after all?

Does your own data converge with itself as you go from half to 3/4 to all of the data? That's a necessary (but not sufficient) criterion.

Are RDFs known to be slow to converge? I have about 1000 water molecules and about 50+ glycine molecules, simulated for 10ns with 1ps sampling intervals. That should give me 500,000,000 data points for the distribution, right? Can I compare this number with the literature in which RDFs for, say, water-water interactions are reported?

How many data points at what interval do they have?

Mark

One important point, which was not really clear to me before was if, provided that I have enough data, the RDFs should be identical no matter whether I use 1, 2, or 3 hydrogen atoms for generating the RDF. As far as I understood, both yours and Omer’s responses indicate that the RDFs should be identical. Did I get that correctly?

Best regards,

Soren

*From:* gmx-users-boun...@gromacs.org [mailto:gmx-users-boun...@gromacs.org] *On Behalf Of *Dallas B. Warren
*Sent:* Thursday, October 22, 2009 6:56 AM
*To:* Discussion list for GROMACS users
*Subject:* RE: [gmx-users] g_rdf and number of atoms to include

Omar’s response answered that question on why they are different. In the first one you are grouping all three into one group, second is just one of the hydrogen types. The fact that the rdf you get is different indicates that all three hydrogens are not identical. Have you compared the rdf for each hydrogen type individually? Another factor may also be that in the first you have three times the number of data points, which can smooth out the curves more.

Catch ya,

Dr. Dallas Warren
Department of Pharmaceutical Biology
Pharmacy and Pharmaceutical Sciences, Monash University
381 Royal Parade, Parkville VIC 3010
dallas.war...@pharm.monash.edu.au
+61 3 9903 9167
---------------------------------
When the only tool you own is a hammer, every problem begins to resemble a nail.

*From:* gmx-users-boun...@gromacs.org [mailto:gmx-users-boun...@gromacs.org] *On Behalf Of *Enemark Soeren
*Sent:* Wednesday, 21 October 2009 8:28 PM
*To:* Discussion list for GROMACS users
*Subject:* RE: [gmx-users] g_rdf and number of atoms to include

Hi Omer,

Thanks for your input.

Let me reformulate my problem:

I have glycine molecules in the form of zwitterions:

 ….

    1ZGLY     N    1   0.560   0.337   0.388 -0.0759 -0.2488 -0.5471

    1ZGLY    H1    2   0.625   0.312   0.461  0.6035  0.5922 -0.4315

    1ZGLY    H2    3   0.601   0.311   0.299  0.1500 -0.3357 -1.5372

    1ZGLY    H3    4   0.553   0.433   0.388  0.5086  2.8817 -1.8023

    1ZGLY    CA    5   0.426   0.272   0.403  0.3095  0.1790 -0.0455

    1ZGLY   HA1    6   0.352   0.335   0.345 -0.9032  0.4782  0.1366

    1ZGLY   HA2    7   0.433   0.173   0.358  0.7875  0.5369 -3.0389

    1ZGLY     C    8   0.378   0.267   0.551  0.1816 -0.4672  0.1868

    1ZGLY   OC1    9   0.449   0.218   0.644 -0.2820 -0.4080  0.2048

    1ZGLY   OC2   10   0.263   0.320   0.559 -0.0662 -0.2935 -0.8010

 ….

Now, I am interested in the interaction between the amine group hydrogen atoms (H1, H2, and H3) and the water oxygen atom. Thus, I define 2 group in an index file:

1. aH1H2H3 (which contains all H1, H2, and H3 atoms in the glycine molecules in my system)

2. aOwat (which contains all oxygen atoms in the water molecules in my system)

However, I also tried setting up a different index file with the groups:

1.       aH1 (which contains all H1 atoms in my system)

2.       aOwat (like before)

I find that these 2 index files do not produce the same RDFs. Why is that?

Best regards,

Soren

*From:* gmx-users-boun...@gromacs.org [mailto:gmx-users-boun...@gromacs.org] *On Behalf Of *Omer Markovitch
*Sent:* Wednesday, October 21, 2009 4:27 PM
*To:* Discussion list for GROMACS users
*Subject:* Re: [gmx-users] g_rdf and number of atoms to include

On Wed, Oct 21, 2009 at 07:28, Enemark Soeren <ch...@nus.edu.sg <mailto:ch...@nus.edu.sg>> wrote:

Dear users,

I would like to compare interactions between molecules by using RDF. I have tried looking at glycine and water, and compare the following two interactions:

1) between the amine hydrogen atoms in glycine and the oxygen atom in water

2) between the carboxyl oxygen atoms in glycine and the oxygen atom in water

However, my result in 1) depends on how many of the 3 hydrogen atoms I include in the calculations. Why is that?

If you mean that when focusing your RDF calculations on either one of the three hydrogens results in three different RDFs then it means that each hydrogen feels water differently. I bet this difference is only for the first peak of g(r) and the other peaks overlap between the three RDFs. As for how reasonable this result, its not unlikely because glycine has atleast 2 different types of hydrogens (say, C-H vs. N-H), depending on the protonation state. You might want to provide more details on the system you are studying to get better answer. I am assuming that the RDFs are converged so that including more trajectory data and/or sampled molecules and/or changing bin size does not result in a drastic change to the curves.

    Does that mean that I cannot directly compare the strengths (RDF
    peak height) of the two interactions as they are not based on the
    same number of atoms? Does it also mean that I must always calculate
    RDFs by using 1 atom on each of the particles/groups that I am
    comparing?

I am not sure how good it is to use the first peak of g(r) to analyze strengths, but you should also consider the width and area under peak. This peak is an average on all nearest neighbours, bonded or not, so it might not give you a good estimate of the hydrogen bond, for example. If you are unsure of your g(r) calc it just for water (that is - only oxygen-oxygen of water-water). At long distances (~10 Angstroms) it should fluctuate around 1.

Bests, Omer Markovitch.


------------------------------------------------------------------------

_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php
_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to