Hi all,
    I have done a simulation about pulling a K+ throug a (9,9)CNT. The results 
may be strange.
    The length of the CNT is 1.477nm,the box is 5*5*5nm.I use the Umbrella 
Sampling to calculate PMF ,following the tutorial by Justin A. Lemkul. I have 
pulled (along Z direction) a K+ (pulling group)frome one end (reference group ) 
of the CNT to another end to generate Configurations for Umbrella Sampling,both 
ends of CNT were fixed. Then I use g_dist to calculate the COM distance between 
K+ and the reference group,the result is strange,the Z direction component -dz 
is negative,it should be positive,because the Z coordinate of K+ is lager than 
that of reference in the .xtc output file. I don't know why. the pulling 
distance is not larger than half of the box size.the Z direction component -dz  
is also negative in Umbrella Sampling windows.
   Then do Umbrella Sampling,the pulling group and reference group is as in COM 
pulling step.pull_geometry = distance,pull_rate = 0. The PMF is negative and 
not symmetry about the middle of the CNT.I think it is wrong.May be it is 
because the dz is negative,or the choice of reference is not proper, it should 
be the middle the CNT as the reference.Anybody could help? Thanks a lot!
; COM PULLING          
; Pull type: no, umbrella, constraint or constant_force
pull                     = umbrella
; Pull geometry: distance, direction, cylinder or position
pull_geometry            = distance 
; Select components for the pull vector. default: Y Y Y
pull_dim                 = N N Y
; Cylinder radius for dynamic reaction force groups (nm)
pull_r1                  = 1
; Switch from r1 to r0 in case of dynamic reaction force
pull_r0                  = 1
pull_constr_tol          = 1e-06
pull_start               = yes
pull_nstxout             = 500
pull_nstfout             = 500
; Number of pull groups 
pull_ngroups             = 1
; Group name, weight (default all 1), vector, init, rate (nm/ps), kJ/(mol*nm^2)
pull_group0              = refer
pull_weights0            = 
pull_pbcatom0            = 0
pull_group1              = K
pull_weights1            = 
pull_pbcatom1            = 0
pull_vec1                = 0 0 0
pull_init1               = 0 
pull_rate1               = 0.0
pull_k1                  = 1000

Zhongjin He




--
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to