Sounds like this is not specific to transition path sampling.

Generally, save the trajectory and run g_dist after mdrun.

If you want to have the distance stored very often, then you should technically be able to add the pull code with a force constant of zero and have the pullx.xvg file track the displacement for you. Be careful though, I have previously run into problems while trying to get too fancy and using things in ways that the either the original developer didn't consider or whose consequences I didn't entirely comprehend. Here, you'll want to test that having a force constant of zero is not going to cause some problem by running a small box of water with such a pull-code restraint on two water molecules and checking that all observables are the same as a control simulation that doesn't use the pull code at all.

Chris.

-- original message --

Dear sir,
                i have been doing something like transition path sampling.i
have the order parameter and i have to monitor the distance between the
ions  how do i monitor the distace between the ions during the course of
simulation.should i include the order parameters in the mdp file.
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://lists.gromacs.org/pipermail/gmx-users/attachments/20101024/2ed92d63/attachment.html


--
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to