Quoting [email protected]:

Send gmx-users mailing list submissions to
        [email protected]

To subscribe or unsubscribe via the World Wide Web, visit
        http://lists.gromacs.org/mailman/listinfo/gmx-users
or, via email, send a message with subject or body 'help' to
        [email protected]

You can reach the person managing the list at
        [email protected]

When replying, please edit your Subject line so it is more specific
than "Re: Contents of gmx-users digest..."


Today's Topics:

   1. Re: nve run of carbon nanotube (Vitaly Chaban)
   2. question (Raymond)
   3. Re: question (Mark Abraham)
   4. Reg: pcoupling and ref_p (vinothkumar mohanakrishnan)


----------------------------------------------------------------------

Message: 1
Date: Tue, 16 Nov 2010 23:48:39 -0500
From: Vitaly Chaban <[email protected]>
Subject: [gmx-users] Re: nve run of carbon nanotube
To: [email protected]
Message-ID:
        <[email protected]>
Content-Type: text/plain; charset=ISO-8859-1

I would not say that you tube rotates so vigorously to be
suspicious... The tube is also very small. What about trying a bigger
one, e.g. with about 1 000 atoms? It should be more inert, if you'd
like it to be such.
ok. I will do that and tell you what happens.

hope this might be useful:
they are top and sideviews
http://www.youtube.com/watch?v=aMMa4o0CzxU
http://www.youtube.com/watch?v=UVksVaHcw8U
http://www.youtube.com/watch?v=xJu3NSkA3gU
http://www.youtube.com/watch?v=cdcyqnPY7D4

So, now the problem becomes why NVE simulation does not preserve
system energy. I did not find above what method you used (MDP file)
for the LJ interactions. I believe the problem is someplace around
this point.
I do not get you, surely the itp & top files will have the information regarding the LJ interactions. As far as i remember for C-C interactions I have C6 and C12 interaction mentioned in [non_bond param] section and also when defining the atom type C I have used the same parameter values, is there anything else i have to take into consideration besides that?
-Adwait

--
Dr. Vitaly Chaban


------------------------------

Message: 2
Date: Wed, 17 Nov 2010 14:52:48 +0800
From: "Raymond" <[email protected]>
Subject: [gmx-users] question
To: "gmx-users" <[email protected]>
Message-ID: <[email protected]>
Content-Type: text/plain; charset="us-ascii"

Skipped content of type multipart/alternative-------------- next part --------------
A non-text attachment was scrubbed...
Name: [email protected]
Type: image/jpeg
Size: 11874 bytes
Desc: not available
Url : http://lists.gromacs.org/pipermail/gmx-users/attachments/20101117/f331bb84/3609746sina.com-0001.jpg

------------------------------

Message: 3
Date: Wed, 17 Nov 2010 19:26:46 +1100
From: Mark Abraham <[email protected]>
Subject: Re: [gmx-users] question
To: Discussion list for GROMACS users <[email protected]>
Message-ID: <[email protected]>
Content-Type: text/plain; charset="iso-8859-1"

On 17/11/2010 5:52 PM, Raymond wrote:
Why my rdf is larger than 1 in the long range
2010-11-17
------------------------------------------------------------------------
Raymond

Probably because you did not measure what you thought you measured :-)

Mark
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://lists.gromacs.org/pipermail/gmx-users/attachments/20101117/07e0447c/attachment-0001.html

------------------------------

Message: 4
Date: Wed, 17 Nov 2010 14:08:54 +0530
From: vinothkumar mohanakrishnan <[email protected]>
Subject: [gmx-users] Reg: pcoupling and ref_p
To: Discussion list for GROMACS users <[email protected]>
Message-ID:
        <[email protected]>
Content-Type: text/plain; charset="iso-8859-1"

Hi Gromacians

I have created two liquid-liquid interfaces by combining three
(DCE-Water-DCE) boxes. I want to calculate the Interfacial surface tension
by using the surface tension option in Gromacs.
I know that I need to give two values for ref_p one for xy and other for z.
it was said in the manual that the "first value should be reference surface
tension times the number of surfaces".what does it mean? what is this
reference surface tension and what value i should put to calculate the
surface tension? i know that the ref_p for z should be 1 bar (correct me if
i am wrong) Further more how come ref_p unit will be bar nm for xy and for z
it will be bar? any help is highly appreciated.

Regards
Vinoth
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://lists.gromacs.org/pipermail/gmx-users/attachments/20101117/0e6ce8d0/attachment.html

------------------------------

--
gmx-users mailing list
[email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/Search before posting!

End of gmx-users Digest, Vol 79, Issue 121
******************************************




-Adwait

----------------------------------------------------------------
This message was sent using IMP, the Internet Messaging Program.

--
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to