On 10/01/2011 2:41 AM, trevor brown wrote:
Dear friends,
My run commands are below. It works without any error.
However if I add -water tip3p at the end of pdg2gmx ... line it causes an error (Atomtpe HW not found) at grompp time.
Could anyone explain the difference?
trevor
pdb2gmx -ignh -f XXX.pdb -o fws.gro -p fws.top
editconf -f fws.gro -bt dodecahedron -d 1.0
editconf -f out.gro -o fws_ctr.gro -center 1.7 1.7 1.2
genbox -cp fws_ctr.gro -cs spc216.gro -o fws_b4em.gro -p fws.top

Not all water models are intended to go with all force fields. G43a1 does not define the HW atom type used for TIP3P water, possibly by Berk's design :-). I don't remember whether it's reasonable to want to use TIP3P with the GROMOS forcefields, but presumably SPC water will work with them.

Mark
--
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to