Andrew Mauro wrote:
Hi,
While running a simulation of capped alanine in an implicit solvent the
molecule appears to collapse on itself such that the atoms have
coordinates of 0,0,0 or some even have NaN. Has anyone else had this
problem or any suggestions?
Sounds like http://www.gromacs.org/Documentation/Terminology/Blowing_Up.
The simulation was run using GROMACS 4.5 with the amber96ff with
brownian dynamics.
Parameters
– Langevin dynamics = bd
– Bd_fric= 95 [amu ps^-1]
– Implicit_solvent= GBSA
– gb_altorithm= OBC
– gb_epsilon_solvent = 80 (dielectric constant of H20)
– Sa_surface_tension = 2.092 [kJ mol^-1 nm^-2 ]
– Thermostat= vscale
A complete .mdp file would be vastly more useful than this parsed version.
There are numerous factors that will influence the stability of your system,
many of which are omitted here.
You can also try upgrading to version 4.5.3, as there have been several bug
fixes and improvements to the implicit solvent code (among others).
-Justin