You must have a different plot to what you sent then, as that graph shows no decay what so ever, it appears to be essentially constant. What that means is on that time scale there is no correlation between the velocity at a point in time and any time on the x axis before/previously.
Catch ya, Dr. Dallas Warren Medicinal Chemistry and Drug Action Monash Institute of Pharmaceutical Sciences, Monash University 381 Royal Parade, Parkville VIC 3010 [email protected] +61 3 9903 9304 --------------------------------- When the only tool you own is a hammer, every problem begins to resemble a nail. From: [email protected] [mailto:[email protected]] On Behalf Of Prema Awati Sent: Monday, 26 September 2011 9:58 PM To: [email protected] Subject: [gmx-users] VACF Hello users, I am trying to calculate VACF of cation and anion of [hmim][tf2n] ionic liquid. I am getting some wierd plot which is decaying along the axis. The jpg of this plot has been attached.Please can someone assist me interpret this plot ; I know its simple but am stucked. Thanks, regards.
-- gmx-users mailing list [email protected] http://lists.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/Search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [email protected]. Can't post? Read http://www.gromacs.org/Support/Mailing_Lists