On 29/12/2011 9:43 PM, michael zhenin wrote:

    Hello,
    I would like to run a simulation using the shell option.
    I tried to restraint solvent molecules which were found within the
    range of 5-10 angstroms from the box center. I couldn't find any
    way to do so. I didn't find any information about this topic
    anywhere else i.e. GROMACS manual, online tutorials etc.


There are some threads in the mailing list archives. You need to make two different moleculetypes, one which is position restrained, and one that isn't. Then you need to identify the ones you want to restrain, e.g. with an index group made by g_select. Then you'll need to do some cut-and-paste to get the block of restrained solvent contiguous.

Mark
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists