On 13 February 2012 20:20, Mark Abraham <[email protected]> wrote:

> On 14/02/2012 6:26 AM, Juliette N. wrote:
>
>> Hi all,
>>
>> I have two simple question on in vacu calculations.
>>
>> 1- Say we start from rc=1, and go all the way to rc=0.1 then we say cut
>> off has been reduced from 1 nm to 0.1 nm meaning that atoms fall within 0.1
>> nm interact with each other. Now when we set rc=0, why dont we consider
>> this as zero cutoff and that No interaction is cacluated for in vacu
>> simulation. When one sets r_vdw= 0, r_coulomb=0, why people call this
>> infinite cutoff and not zero cutoff (=no nonboded interaction calculated).
>>
>
> Because it is defined that way. See manual section 7.3.9. In theory, you
> could have another .mdp variable "cut-offs = yes/no" to serve this purpose,
> but since the value zero serves no useful purpose, it is used in the above
> way.
>
> Thank Mark. Can you please tell me rc=0 means all nonbonded interaction
> are calculated (i.e. infinite cut off) or no interaction is calculated
> (i.e. zero cut off; only bonded interactions) ? I am asking this because I
> have seen on the list that rc=0 is referred to as infinite cutoff.
>
>>
>> 2-For calculation of heat of vaporisation why do we need single molecule
>> in vacu? why cant we leave cut off as in liquid phase?
>>
>> 3- Also why do we turn off PBC for in vacu runs?
>>
>
> Usually efficiency. Finding the nearest neighbours takes time, and if
> there are few atoms at all (as is often the case with vacuum simulations)
> it can be cheaper just to compute all the interactions.
>
> Mark
>
-- 
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to