On 17/02/2012 4:46 PM, James Starlight wrote:
So my problem still is

1) During npt without peptide my Ccl4 system expan rapidly in X-dimension. That produce error on 2nd ns of equilibration

One of the box vectors has become shorter than twice the cut-off length or box_yy-|box_zy| or box_zz has become smaller than the cut-off.

2) During npt with peptide my system expan rapidly in Z direction ( along that axe my peptide is oriented) So as concequence I've obtained the same error.

What does a cube of CCl4 do? If it is not stable at an acceptable density then your parameters don't work at all. Starting with simple things and adding complexity gradually is always a good policy, even when you're an expert. There's so many things that can be slightly wrong...


Possible sollution wich I've found in litterature

1) To fix one dimension of my PB. How I could fix the X dimension of my box during npt phace of pure Ccl4 and allow only change in 2 other dimensions ?

See pcoupltype in manual 7.3.15


2) I have not found radius for Cl for Gromos56 ff.
Is this possible to decrease that value during npt phase to obtain system with desired hight density? What value should I use?

As someone else said, the radius is only material during things like genbox. In the simulation, your nonbonded parameters are the important thing.

Mark
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to