On 6/03/2012 6:58 PM, Tom Kirchner wrote:
Dear all,
I made a free energy calculation and want to evaluate my data with
g_bar. But when I am using g_bar on my .xvg files I get an error of the
form:
Temperature in file md_0.35.xvg different from earlier files or
setting
All simulations were performed at temperature 298.15 K, this number is
also written in the .xvg files and the same for all of them. An older
setup worked fine a the temperature of 300 K. After I changed the
temperature of my new files also to 300 K, g_bar now works.
Is it possible, that g_bar can not handle real numbers?
Unlikely. You can perhaps probe that by using 300.0 and 300.1.
When suggesting the existence of a bug, people need to be explicit about
the conditions that might replicate it - so GROMACS version and actual
command lines and (here) copies of headers of .xvg files are absolutely
necessary. To get traction, you need to overcome the normal assumption
of the developer that they've coded it right and you're using it wrongly
:-) Information is the key to achieving that.
Mark
--
gmx-users mailing list [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists