Hi.
I am trying to the the PMF of transferring a drug molecule from the aqueous 
phase to a lipid bilayer.
In order to minimize the effects of membrane undulations I tried to use 
pull_geometry=cylinder.
Whenever I run a short simulation with umbrella sampling starting from a 
configuration with the drug molecule way above the bilayerthe drug molecule is 
pulled into the bilayer rather rapidly. It appears as if the distance between 
the cylinder's COM and the drug molecule's COM is supposed to be zero since it 
is pulled to the center of the membrane. 
Since I apply an umbrella potential I find this weird and I would of course 
like the molecule to"stay put" at that current z-position. Probably I set up 
the pull code wrong. Here are my options:
pull                    = umbrellapull_geometry     = cylinderpull_dim          
   = N N Ypull_ngroups           = 1pull_rate1           = 0.0pull_k1           
 = 1000pull_start            = yespull_init1             = 0.0pull_vec1         
   = 0.0 0.0 1.0pull_pbcatom0     = 0pull_ngroups        = 1pull_group0         
= DPPCpull_group1          = drug
Have not decided the radii of the cylinder yet, but that is besides the point 
here.
I run with the 4.5.5 version and cannot figure what the problem is.             
                          
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to