Dear gmxers,
I have prepared the inputs and tried to run constraint distance pulling on
two-molecule pair. However, one error is output which indicates that two atoms
on the molecule including the pull group are beyond the 1-4 table range. I have
chosen one reference group and one pull group. And both groups are parts of
whole molecules. I find that no error is given when only pull opinions are
commented out. So I guess this error can be caused by the pull code, i.e., the
pull group is suddently moved to the distance defined by pull_init1, but the
rest of molecule is not moved a bit, which leads to one much bigger 1-4
distance. Is it right? Cannot the pull code deal with the two groups belonging
to only parts of two molecules? Please give me some hints, thanks a lot.
Chaofu Wu
------------------
Department of Chemistry and Materials Science
Hunan University of Humanities, Science and Technology,
Loudi 417000, the People's Republic of China (P.R. China)
--
gmx-users mailing list [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists