On 5/06/2012 4:34 PM, Bao Kai wrote:
Hi, all,

I am still trying to do my simulation with liquid mixtures.

I have a simple question now. When I writing my .top file, how could I
know if I should use epsilon-sigma or c6-c12 parameters for the LJ
potential? It seems that in some examples, c6-c12 parameters are used
and epsilon-sigma parameters are used in some other examples.

The model you are implementing chooses this and the rule by which parameters of different atom types get combined into interaction type parameters. The rationale for that choice often seems vague, IMO probably doesn't matter much, and is not really your problem until you go to design models. Literature is your friend, here.

Mark
--
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists