Yea – turning of CCR means shutting down the entire cluster. Not an option.

CCR is VERY POORLY documented.

Bob Oesterlin
Sr Storage Engineer, Nuance HPC Grid

From: 
<[email protected]<mailto:[email protected]>>
 on behalf of Jan-Frode Myklebust 
<[email protected]<mailto:[email protected]>>
Reply-To: gpfsug main discussion list 
<[email protected]<mailto:[email protected]>>
Date: Thursday, April 14, 2016 at 2:33 PM
To: gpfsug main discussion list 
<[email protected]<mailto:[email protected]>>
Subject: Re: [gpfsug-discuss] CCR error messages after mmsdrrestore

I would try switching from CCR to primary/secondary config servers, maybe 
delete the paxos files, and then back to CCR.


I believe that's how I got out of a similar situation on a v4.1.1.x 
installation this january..


_______________________________________________
gpfsug-discuss mailing list
gpfsug-discuss at spectrumscale.org
http://gpfsug.org/mailman/listinfo/gpfsug-discuss

Reply via email to