In general, yes, it's common practice to do the 'rolling upgrades'. If I had to 
do my whole cluster at once, with an outage, I'd probably never upgrade. :)


Bob Oesterlin
Sr Storage Engineer, Nuance HPC Grid


From: <[email protected]> on behalf of "Sobey, Richard 
A" <[email protected]>
Reply-To: gpfsug main discussion list <[email protected]>
Date: Monday, August 15, 2016 at 4:59 AM
To: "'[email protected]'" <[email protected]>
Subject: [EXTERNAL] [gpfsug-discuss] Minor GPFS versions coexistence problems?

Hi all,

If I wanted to upgrade my NSD nodes one at a time from 3.5.0.22 to 3.5.0.27 (or 
whatever the latest in that branch is) am I ok to stagger it over a few days, 
perhaps up to 2 weeks or will I run into problems if they’re on different 
versions?

Cheers

Richard