You can use both -HAWC ,LROC- on the same node... but you need dedicated
,independent ,block devices ...
In addition for hawc, you could consider replication and use 2 devices, even
across 2 nodes. ...
Gesendet von IBM Verse
leslie elliott --- [gpfsug-discuss] HAWC and LROC ---
Von:"leslie elliott" <[email protected]>An:"gpfsug main
discussion list" <[email protected]>Datum:Sa. 05.11.2016
02:09Betreff:[gpfsug-discuss] HAWC and LROC
Hi I am curious if anyone has run these together on a client and whether
it helped
If we wanted to have these functions out at the client to optimise
compute IO in a couple of special cases
can both exist at the same time on the same nonvolatile hardware or do
the two functions need independent devices
and what would be the process to disestablish them on the clients as the
requirement was satisfied
thanks
leslie