it's all true and right, but please have in mind.. with MFTC and the number of nodes  in the ( remote and local ) cluster, you 'll need token mem
since R42 token Mem is allocated automatically .. so the old tokenMEMLimit is more or less obsolete.. but you should have your overall configuration in mind, when raising MFTC clusterwide...

just a hint..

have fun...
Mit freundlichen Grüßen / Kind regards

 
Olaf Weiser

EMEA Storage Competence Center Mainz, German / IBM Systems, Storage Platform,
-------------------------------------------------------------------------------------------------------------------------------------------
IBM Deutschland
IBM Allee 1
71139 Ehningen
Phone: +49-170-579-44-66
E-Mail: [email protected]
-------------------------------------------------------------------------------------------------------------------------------------------
IBM Deutschland GmbH / Vorsitzender des Aufsichtsrats: Martin Jetter
Geschäftsführung: Martina Koederitz (Vorsitzende), Susanne Peter, Norbert Janzen, Dr. Christian Keller, Ivo Koerner, Markus Koerner
Sitz der Gesellschaft: Ehningen / Registergericht: Amtsgericht Stuttgart, HRB 14562 / WEEE-Reg.-Nr. DE 99369940




From:        "Oesterlin, Robert" <[email protected]>
To:        gpfsug main discussion list <[email protected]>
Date:        12/20/2016 08:19 PM
Subject:        Re: [gpfsug-discuss] LROC
Sent by:        [email protected]




We’re currently deploying LROC in many of our compute nodes – results so far have been excellent. We’re putting in 240gb SSDs, because we have mostly small files. As far as I know, the amount of inodes and directories in LROC are not limited, except by the size of the cache disk.
 
Look at these config options for LROC:
 
lrocData
Controls whether user data is populated into the local read-only cache. Other configuration options can be used to select the data that is eligible for the local read-only cache. When using more than one such configuration option, data that matches any of the specified criteria is eligible to be saved.
Valid values are yes or no. The default value is yes.
If lrocData is set to yes, by default the data that was not already in the cache when accessed by a user is subsequently saved to the local read-only cache. The default behavior can be overridden using thelrocDataMaxFileSize and lrocDataStubFileSizeconfiguration options to save all data from small files or all data from the initial portion of large files.
lrocDataMaxFileSize
Limits the data that may be saved in the local read-only cache to only the data from small files.
A value of -1 indicates that all data is eligible to be saved. A value of 0 indicates that small files are not to be saved. A positive value indicates the maximum size of a file to be considered for the local read-only cache. For example, a value of 32768 indicates that files with 32 KB of data or less are eligible to be saved in the local read-only cache. The default value is 0.
lrocDataStubFileSize
Limits the data that may be saved in the local read-only cache to only the data from the first portion of all files.
A value of -1 indicates that all file data is eligible to be saved. A value of 0 indicates that stub data is not eligible to be saved. A positive value indicates that the initial portion of each file that is eligible is to be saved. For example, a value of 32768 indicates that the first 32 KB of data from each file is eligible to be saved in the local read-only cache. The default value is 0.
lrocDirectories
Controls whether directory blocks is populated into the local read-only cache. The option also controls other file system metadata such as indirect blocks, symbolic links, and extended attribute overflow blocks.
Valid values are yes or no. The default value is yes.
lrocInodes
Controls whether inodes from open files is populated into the local read-only cache; the cache contains the full inode, including all disk pointers, extended attributes, and data.
Valid values are yes or no. The default value is yes.
 
 
Bob Oesterlin
Sr Principal Storage Engineer, Nuance
507-269-0413

 
 
 
From: <[email protected]> on behalf of Matt Weil <[email protected]>
Reply-To:
gpfsug main discussion list <[email protected]>
Date:
Tuesday, December 20, 2016 at 1:13 PM
To:
"[email protected]" <[email protected]>
Subject:
[EXTERNAL] Re: [gpfsug-discuss] LROC

 

as many as possible and both

have maxFilesToCache 128000

and maxStatCache 40000

do these effect what sits on the LROC as well?  Are those to small? 1million seemed excessive.
 
On 12/20/16 11:03 AM, Sven Oehme wrote:
how much files do you want to cache ?  
and do you only want to cache metadata or also data associated to the files ?
 
sven
 
 
 
On Tue, Dec 20, 2016 at 5:35 PM Matt Weil <[email protected]> wrote:
https://www.ibm.com/developerworks/community/wikis/home?lang=en#!/wiki/General%20Parallel%20File%20System%20(GPFS)/page/Flash%20Storage

Hello all,

Are there any tuning recommendations to get these to cache more metadata?

Thanks

Matt

_______________________________________________
gpfsug-discuss mailing list
gpfsug-discuss at
spectrumscale.org
http://gpfsug.org/mailman/listinfo/gpfsug-discuss



_______________________________________________
gpfsug-discuss mailing list
gpfsug-discuss at spectrumscale.org
http://gpfsug.org/mailman/listinfo/gpfsug-discuss

_______________________________________________
gpfsug-discuss mailing list
gpfsug-discuss at spectrumscale.org
http://gpfsug.org/mailman/listinfo/gpfsug-discuss



_______________________________________________
gpfsug-discuss mailing list
gpfsug-discuss at spectrumscale.org
http://gpfsug.org/mailman/listinfo/gpfsug-discuss

Reply via email to