On Tue, Apr 14, 2020 at 03:54:41PM -0400, Clark Case wrote: > Hi - I have a Canon G5 X. It exposes zoom through a config called "zoom" > and aperture through a config called "aperture". Both are in a section > called capturesettings. > > I can read both settings. But when I try to set them, the camera hangs up. > I get no useful output when I try to set it the first time, but subsequent > attempts indicate a timeout. See output below. > > Any suggestions for how to debug this further? > > Thanks, > Clark > > ubuntu@ubuntu:~$ gphoto2 --get-config zoom > Label: Zoom > > Readonly: 0 > Type: TEXT > Current: 75 > END > ubuntu@ubuntu:~$ env LANG=C gphoto2 --debug --debug-logfile=my-logfile.txt > --set-config zoom=0 > ubuntu@ubuntu:~$ env LANG=C gphoto2 --debug --debug-logfile=my-logfile.txt > --set-config zoom=75 > > > *** Error *** > PTP Timeout > > *** Error *** > An error occurred in the io-library ('Timeout reading from or writing to > the port'): No error description available > > *** Error *** > PTP Timeout > > *** Error *** > An error occurred in the io-library ('Timeout reading from or writing to > the port'): No error description available > *** Error (-10: 'Timeout reading from or writing to the port') ***
Can you attach the debug log? the reated my-logfile.txt from above call? Ciao, Marcus _______________________________________________ Gphoto-devel mailing list Gphoto-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/gphoto-devel