Hello,

I ask Helena and she gave me the anwser. You have to use a parameter "zmult" 
with v.vol.rst (I try some values between 180 and 10 and choose zmult=50 for my 
question) . How to use "zmult" is not described in the help until now.

Regards.








> -----Ursprüngliche Nachricht-----
> Von: Stuart Edwards <[EMAIL PROTECTED]>
> Gesendet: 16.06.07 18:33:03
> An: Christian Butzeck <[EMAIL PROTECTED]>
> CC: [email protected]
> Betreff: Re: [GRASS-user] Problem with v.vol.rst and 3d-interpolation


> 
> Maybe try adding some 'dummy' data points at the top of the clay  
> layer and the water table to force the analysis.  Try adding a series  
> of points in the top 1m of the clay (say every 0.1m) with a value of  
> 0.000001 mg/L) and the same in the 1m interval above the water  
> table.  Not very elegant, but it will probably pull the interpolated  
> values back into the aquifer.  Let me know if it works --
> 
> Stu