I believe the major problem with energy losses is that your system
never achieves equilibrium.

Thus, all the simulated properties are not what they need to be...




Dr. Vitaly V. Chaban

Виталий Витальевич ЧАБАН


On Sun, Oct 12, 2014 at 5:31 PM, Dr. Vitaly Chaban <vvcha...@gmail.com> wrote:
> The artifacts are caused by energy leakage. Thermostatting does not
> solve them. The problem exists, but you do not see it clearly with
> thermostat. For instance, I have an example where a liquid droplet in
> vacuum is not stable due to bad energy conservation. Some particles
> just sporadically fly away over the course of the simulation.
>
> NVE generally does not like constraints. If I remember correctly from
> the previous messages, you use constraints. Novel performance
> improvements in gromacs (accumulated after 4.0 and especially after
> 4.5) sometimes compromise accuracy, though it is a long discussion
> itself. What about downgrading to gmx 4.0 or gmx 3.3, after all? The
> very last time I used gromacs for NVE simulation was in 2009. I guess
> I used gmx 3.3.3 (but maybe 4.0.x). There were no problems for sure.
>
> I would also give a try to some very simple system (e.g. liquid argon)
> to observe what happens to total energy.
>
> Good luck with troubleshooting!
>
>
> Dr. Vitaly V. Chaban
>
> Виталий Витальевич ЧАБАН
>
>
> On Sun, Oct 12, 2014 at 4:53 PM, Johnny Lu <johnny.lu...@gmail.com> wrote:
>>  Firstly, what are the possible errors/artifacts caused by masking "the
>> energy leakage problem with the thermostat" in this case?
>>
>> Secondly, are there any other mdp setting that I can try to make the mixed
>> precision gromacs NVE run have conserved energy over 100 ns ? (and... is it
>> because of some errors that I made in my systems that make the NVE run not
>> conserved in energy?)
>>
>> The NVE has the following statistics.
>>
>> Statistics over 2747281 steps [ 0.0000 through 1373.6400 ps ], 4 data sets
>> All statistics are over 274729 points
>>
>> Energy                      Average   Err.Est.       RMSD  Tot-Drift
>> -------------------------------------------------------------------------------
>> Disper. corr.              -3961.13          0          0 2.60178e-09
>> (kJ/mol)
>> Total Energy                -309939        160     337.76    478.828
>> (kJ/mol)
>> Temperature                 300.292       0.24    1.49289   0.631428  (K)
>> Pressure                   -64.5409        4.7    148.779    25.1326  (bar)
>> --
>> Gromacs Users mailing list
>>
>> * Please search the archive at 
>> http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!
>>
>> * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
>>
>> * For (un)subscribe requests visit
>> https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
>> mail to gmx-users-requ...@gromacs.org.
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to