On 1/15/15 12:20 PM, Jennifer Vo wrote:
Dear Experts,
I ran a grompp (gromos53a6 ff)
grompp -f em.mdp -c complex2_solvated.gro -p topol.top -o complex.tpr
and it generated the error
Atomtype P,SI not found
I checked the gromos53a6.ff/atomtypes.atp and see there are P, SI in the
list
SI 28.08 ; Silicon
P 30.97380 ; Phosphor
And there is no P, SI in my complex2_solvated.gro file! I really do
appreciate for any help.
It's an atom type, so it won't be in a coordinate file. Something in a topology
or force field file is specifying something called "P,SI" as an atomtype.
That's clearly not sensible.
-Justin
--
==================================================