On 5/25/16 9:21 AM, Wang Tao wrote:
Hi,Dr Justin!
You have mentioned that i missed my itp file.Here is it
##########
<oh.itp>
[ moleculetype ]
;molname nrexcl
OHIN 1
[ atoms ]
;id at type res nr residue name at name cg nr charge mass
1 opls_434 1 OHIN OH 1 -1.300 15.999
2 opls_435 1 OHIN HO 2 0.300 1.008
[ bonds ]
;i j funct length force.c
1 2 1 0.09450 462750.4;
##########
As you can see, that is how i defined the itp file of OH-.
Those parameters can be found in oplsaa.ff/ffbonded.itp and
oplsaa.ff/ffnonbonded.itp files.They have been provided in gromacs version
4.6.7.
Here are they:
##########
<ffbonde.itp>
HO OH 1 0.09450 462750.4 ; SUG(OL) wlj mod 0.96-> 0.945
##########
<ffnonbonded.itp>
opls_434 OH 8 15.99940 -1.300 A 3.20000e-01 1.04600e+00
opls_435 HO 1 1.00800 0.300 A 0.00000e+00 0.00000e+00
##########
But i really don't understand why the bond in OH- is invalid.Or in another
word,what can i do to finish an sucessful energy minimization with OH- in my
system?
No idea; it works for me. I built a system of one OH- in vacuo, applied your
topology, and it worked fine. Probably something in the .top is broken, and
#include statement in the wrong place or something else.
-Justin
You also said that waht i am conduncting is not a true constant PH MD.Yes,you
are right.I did have some misunderstanding about it. But in my system ,i
intended to create an environment where there is plenty of OH-with fixed
concentration of it.So fixed protonation is ok in this work. But anyway, i am
very interested in constant-PH MD,and want to do something about it.I would
spend more time on it.
Now,would you please offer me some advice on solve my problem above?
Tao Wang
Thank You!
Message: 2
Date: Wed, 25 May 2016 07:04:59 -0400
From: Justin Lemkul <jalem...@vt.edu>
To: gmx-us...@gromacs.org
Subject: Re: [gmx-users] gromacs energy minimization fatal error:
Invalid bond type 1000 in constant-PH MD
Message-ID: <fe760a05-25f0-7190-0003-139be796e...@vt.edu>
Content-Type: text/plain; charset=windows-1252; format=flowed
On 5/25/16 6:06 AM, Wang Tao wrote:
Hi,every one!
I'm using opls aa in gromacs to conduct constant-PH MD. In my system,PH is
equal to 13.There are three kind of groups, NA+,OH- and H2O. The itp file for
OH- is created by myself.
This is not what constant pH MD is. You've got a fixed protonation state with
OH- floating around, which may not be physically realistic.
After having finished the genbox and genion steps sucessfully, i met a problem
in energy minimization step. The output information says:Invalid bond type
1000. But i don't really understand what the exact problem is.
Tried to remove bond definition in itp file for OH-, don't work.
Tried to remove bond definition in ffbonded.itp for OH-, don't work.
Replaced OH- with CL-,error infomation disappeared.
I believe the problem is related to OH- force field parameters,but don't know
how to deal with it.
You haven't provided us with its topology, so there's nothing anyone can do but
guess haphazardly. But if removing it solves the problem, you know exactly
where the issue is.
-Justin
Can anyone help me?
Tao Wang
Thank You!
--
==================================================
Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow
Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 629
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201
jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul
==================================================
--
==================================================
Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow
Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 629
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201
jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul
==================================================
--
Gromacs Users mailing list
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a
mail to gmx-users-requ...@gromacs.org.