On 8/29/17 1:47 AM, Simon Kit Sang Chu wrote:
Dear every user,
I am using Andersen thermostat and nstcomm should be set to 1 (step).
However, after specifying nstcomm = 1, an error has returned -
nstcalenergy cannot be smaller than nstcomm. GROMACS automatically sets it
to nstcalenergy step.
I fail to search for "nstcalenergy" in neither mdp nor manual.
It's there, and has been for several years:
http://manual.gromacs.org/documentation/2016.3/user-guide/mdp-options.html#output-control
If you're using an algorithm that requires global summation of energy
terms, or otherwise limited by algorithmic requirements as you are here,
you have to sum the energies at every step. This slows things down, but
in some cases (like yours) it's required.
-Justin
--
==================================================
Justin A. Lemkul, Ph.D.
Assistant Professor
Virginia Tech Department of Biochemistry
303 Engel Hall
340 West Campus Dr.
Blacksburg, VA 24061
jalem...@vt.edu | (540) 231-3129
http://www.biochem.vt.edu/people/faculty/JustinLemkul.html
==================================================
--