On 3/11/18 8:05 PM, Alex wrote:
Just to add to my question... The pull code for the umbrella sampling from each of the N configs, as used in Justin's tutorial, is

pull_coord1_type        = umbrella
pull_coord1_geometry    = distance
...
pull_coord1_dim         = N N Y

So, in each of the generated pullf and pullx files we sample a flat slice at a given Z, and the reported forces and displacements are along Z. What appears to be the reaction coordinate in our case is the radius from the pore mouth, and one has to sample a set of hemispheres from a series of radius values. Is this at all a possibility?


Yes, but not by following the tutorial. You'd need to use pull_coord1_dim = Y Y Y to restrict the ions to a given radius around the pore itself. As it is, you're probably underestimating entropic contributions to the free energy.

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Assistant Professor
Virginia Tech Department of Biochemistry

303 Engel Hall
340 West Campus Dr.
Blacksburg, VA 24061

jalem...@vt.edu | (540) 231-3129
http://www.biochem.vt.edu/people/faculty/JustinLemkul.html

==================================================

--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.