Dear gmx users
I am developing a C++ code for simulation of electric double layer.
Currently, I am calculating interaction energy of a system of water
molecules (TIP4P model) in a cell and checking the results with that of
GROMACS. I created a cubic box of size 120 angstroms with 909 molecules at
its center. I have implemented Ewald sum in my code.
The long range part matches but the short range value differs by about 8kJ
from that of GROMACS. I have attached the relevant files here. Can anyone
suggest where I might be going wrong? I have already checked my code
multiple times.


https://drive.google.com/open?id=1G11t_jWqeD_-9DXsP9TiqILeuh7xAXm0

Thank You!
Regards
Kumari Shilpa
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to