I was looking through the 1.4.182 code and I noticed that the 
H2.engine.Database.close(...) method will never process some shutdown code 
if this flag is set to FALSE.

I have it set to FALSE in my case because I have my own shutdown hook that 
stops execution threads in my application and some of those threads may 
need to do some final updates to the database on the way down.
In my case I know the database is running embedded and so I am not 
concerned about additional JDBC connections during my shutdownhook.  

However, based on the code, should I be concerned that clean up code in the 
close() method will never be run?

-- 