Hi,

I installed Solaris Cluster Express 12/08 on 2 pvm virtual nodes (on 2
physical SXCE104 machines).

Each virtual node has 3 NICs (3 VNICs from xVM dom0),
but each physical node has only one physical NIC connected to the one
physical switch. I know about security issues and such...

There is a problem with interconnects so I can't create the cluster.

Any idea? :)



[root at node1 ~]# /usr/cluster/bin/clnode status -v

=== Cluster Nodes ===

--- Node Status ---

Node Name                                                       Status
---------                                                       ------
node1                                                           Online
node2                                                           Offline


--- Node IPMP Group Status ---

Node Name        Group Name        Status        Adapter        Status
---------        ----------        ------        -------        ------
node1            sc_ipmp0          Online        xnf0           Online


[root at node1 ~]# /usr/cluster/bin/clintr show

=== Transport Cables ===

Transport Cable:                                node1:xnf1,switch1 at 1
  Endpoint1:                                       node1:xnf1
  Endpoint2:                                       switch1 at 1
  State:                                           Enabled

Transport Cable:                                node1:xnf2,switch2 at 1
  Endpoint1:                                       node1:xnf2
  Endpoint2:                                       switch2 at 1
  State:                                           Enabled

Transport Cable:                                node2:xnf1,switch1 at 2
  Endpoint1:                                       node2:xnf1
  Endpoint2:                                       switch1 at 2
  State:                                           Enabled

Transport Cable:                                node2:xnf2,switch2 at 2
  Endpoint1:                                       node2:xnf2
  Endpoint2:                                       switch2 at 2
  State:                                           Enabled


=== Transport Switches ===

Transport Switch:                               switch1
  State:                                           Enabled
  Type:                                            switch
  Port Names:                                      1 2
  Port State(1):                                   Enabled
  Port State(2):                                   Enabled

Transport Switch:                               switch2
  State:                                           Enabled
  Type:                                            switch
  Port Names:                                      1 2
  Port State(1):                                   Enabled
  Port State(2):                                   Enabled


--- Transport Adapters for node1 ---

Transport Adapter:                              xnf1
  State:                                           Enabled
  Transport Type:                                  dlpi
  device_name:                                     xnf
  device_instance:                                 1
  lazy_free:                                       1
  dlpi_heartbeat_timeout:                          10000
  dlpi_heartbeat_quantum:                          1000
  nw_bandwidth:                                    80
  bandwidth:                                       70
  ip_address:                                      172.16.0.129
  netmask:                                         255.255.255.128
  Port Names:                                      0
  Port State(0):                                   Enabled

Transport Adapter:                              xnf2
  State:                                           Enabled
  Transport Type:                                  dlpi
  device_name:                                     xnf
  device_instance:                                 2
  lazy_free:                                       1
  dlpi_heartbeat_timeout:                          10000
  dlpi_heartbeat_quantum:                          1000
  nw_bandwidth:                                    80
  bandwidth:                                       70
  ip_address:                                      172.16.1.1
  netmask:                                         255.255.255.128
  Port Names:                                      0
  Port State(0):                                   Enabled


--- Transport Adapters for node2 ---

Transport Adapter:                              xnf1
  State:                                           Enabled
  Transport Type:                                  dlpi
  device_name:                                     xnf
  device_instance:                                 1
  lazy_free:                                       1
  dlpi_heartbeat_timeout:                          10000
  dlpi_heartbeat_quantum:                          1000
  nw_bandwidth:                                    80
  bandwidth:                                       70
  ip_address:                                      172.16.0.130
  netmask:                                         255.255.255.128
  Port Names:                                      0
  Port State(0):                                   Enabled

Transport Adapter:                              xnf2
  State:                                           Enabled
  Transport Type:                                  dlpi
  device_name:                                     xnf
  device_instance:                                 2
  lazy_free:                                       1
  dlpi_heartbeat_timeout:                          10000
  dlpi_heartbeat_quantum:                          1000
  nw_bandwidth:                                    80
  bandwidth:                                       70
  ip_address:                                      172.16.1.2
  netmask:                                         255.255.255.128
  Port Names:                                      0
  Port State(0):                                   Enabled


[root at node1 ~]# /usr/cluster/bin/clintr status -v

=== Cluster Transport Paths ===

Endpoint1                       Endpoint2                       Status
---------                       ---------                       ------
node1:xnf2                      node2:xnf2                      faulted
node1:xnf1                      node2:xnf1                      faulted



Jan 10 11:22:14 node1 genunix: [ID 965873 kern.notice] NOTICE: CMM: Node
node1 (nodeid = 1) with votecount = 1 added.
Jan 10 11:22:14 node1 genunix: [ID 843983 kern.notice] NOTICE: CMM: Node
node1: attempting to join cluster.
Jan 10 11:22:14 node1 genunix: [ID 525628 kern.notice] NOTICE: CMM:
Cluster has reached quorum.
Jan 10 11:22:14 node1 genunix: [ID 377347 kern.notice] NOTICE: CMM: Node
node1 (nodeid = 1) is up; new incarnation number = 1231582933.
Jan 10 11:22:14 node1 genunix: [ID 108990 kern.notice] NOTICE: CMM:
Cluster members: node1.
Jan 10 11:22:14 node1 genunix: [ID 279084 kern.notice] NOTICE: CMM: node
reconfiguration #1 completed.
Jan 10 11:22:17 node1 genunix: [ID 499756 kern.notice] NOTICE: CMM: Node
node1: joined cluster.
Jan 10 11:22:17 node1 ip: [ID 856290 kern.notice] ip: joining multicasts
failed (18) on clprivnet0 - will use link layer broadcasts for multicast
Jan 10 11:22:28 node1 Cluster.CCR: [ID 914260 daemon.warning] Failed to
retrieve global fencing status from the global name server
Jan 10 11:22:28 node1 last message repeated 1 time
Jan 10 11:22:48 node1 Cluster.CCR: [ID 409585 daemon.error]
/usr/cluster/bin/scgdevs: Cannot register devices as HA.
Jan 10 11:22:53 node1 xntpd[909]: [ID 702911 daemon.notice] xntpd
3-5.93e+sun 03/08/29 16:23:05 (1.4)
Jan 10 11:22:53 node1 xntpd[909]: [ID 301315 daemon.notice] tickadj = 5,
tick = 10000, tvu_maxslew = 495, est. hz = 100
Jan 10 11:22:53 node1 xntpd[909]: [ID 266339 daemon.notice] using kernel
phase-lock loop 0041, drift correction 0.00000
Jan 10 11:22:53 node1 last message repeated 1 time
Jan 10 11:23:00 node1 : [ID 386282 daemon.error] ccr_initialize failure
Jan 10 11:23:04 node1 last message repeated 8 times
Jan 10 11:23:04 node1 svc.startd[8]: [ID 748625 daemon.error]
system/cluster/scdpm:default failed repeatedly: transitioned to
maintenance (see 'svcs -xv' for details)
Jan 10 11:24:01 node1 xpvd: [ID 395608 kern.info] xenbus at 0, xenbus0
Jan 10 11:24:01 node1 genunix: [ID 936769 kern.info] xenbus0 is
/xpvd/xenbus at 0
Jan 10 11:28:15 node1 genunix: [ID 965873 kern.notice] NOTICE: CMM: Node
node2 (nodeid = 2) with votecount = 0 added.
Jan 10 11:28:15 node1 genunix: [ID 108990 kern.notice] NOTICE: CMM:
Cluster members: node1.
Jan 10 11:28:15 node1 genunix: [ID 279084 kern.notice] NOTICE: CMM: node
reconfiguration #2 completed.
Jan 10 11:28:16 node1 genunix: [ID 884114 kern.notice] NOTICE: clcomm:
Adapter xnf1 constructed
Jan 10 11:28:16 node1 ip: [ID 856290 kern.notice] ip: joining multicasts
failed (18) on clprivnet0 - will use link layer broadcasts for multicast
Jan 10 11:28:16 node1 genunix: [ID 884114 kern.notice] NOTICE: clcomm:
Adapter xnf2 constructed
Jan 10 11:28:25 node1 rpc_scadmd[1196]: [ID 801593 daemon.notice] stdout:
Jan 10 11:28:25 node1 rpc_scadmd[1196]: [ID 801593 daemon.notice] stderr:
Jan 10 11:28:26 node1 rpc_scadmd[1196]: [ID 801593 daemon.notice] stdout:
Jan 10 11:28:26 node1 rpc_scadmd[1196]: [ID 801593 daemon.notice] stderr:
Jan 10 11:29:16 node1 genunix: [ID 604153 kern.notice] NOTICE: clcomm:
Path node1:xnf1 - node2:xnf1 errors during initiation
Jan 10 11:29:16 node1 genunix: [ID 618107 kern.warning] WARNING: Path
node1:xnf1 - node2:xnf1 initiation encountered errors, errno = 62.
Remote node may be down or unreachable through this path.
Jan 10 11:29:16 node1 genunix: [ID 604153 kern.notice] NOTICE: clcomm:
Path node1:xnf2 - node2:xnf2 errors during initiation
Jan 10 11:29:16 node1 genunix: [ID 618107 kern.warning] WARNING: Path
node1:xnf2 - node2:xnf2 initiation encountered errors, errno = 62.
Remote node may be down or unreachable through this path.
Jan 10 11:30:24 node1 genunix: [ID 537175 kern.notice] NOTICE: CMM: Node
node2 (nodeid: 2, incarnation #: 1231583261) has become reachable.
Jan 10 11:30:24 node1 xnf: [ID 601036 kern.warning] WARNING: xnf2:
oversized packet (1518 bytes) dropped
Jan 10 11:30:24 node1 last message repeated 1 time
Jan 10 11:30:24 node1 genunix: [ID 387288 kern.notice] NOTICE: clcomm:
Path node1:xnf2 - node2:xnf2 online
Jan 10 11:30:24 node1 genunix: [ID 387288 kern.notice] NOTICE: clcomm:
Path node1:xnf1 - node2:xnf1 online
Jan 10 11:30:28 node1 xnf: [ID 601036 kern.warning] WARNING: xnf2:
oversized packet (1518 bytes) dropped
Jan 10 11:30:54 node1 last message repeated 2 times
Jan 10 11:30:54 node1 xnf: [ID 601036 kern.warning] WARNING: xnf1:
oversized packet (1518 bytes) dropped
Jan 10 11:31:08 node1 last message repeated 2 times
Jan 10 11:31:28 node1 xnf: [ID 601036 kern.warning] WARNING: xnf2:
oversized packet (1518 bytes) dropped
Jan 10 11:32:28 node1 last message repeated 1 time
Jan 10 11:33:29 node1 genunix: [ID 489438 kern.notice] NOTICE: clcomm:
Path node1:xnf2 - node2:xnf2 being drained
Jan 10 11:33:29 node1 genunix: [ID 387288 kern.notice] NOTICE: clcomm:
Path node1:xnf2 - node2:xnf2 online




[root at node1 ~]# uname -a
SunOS node1 5.11 snv_101a i86pc i386 i86xpv



# xm start -c node2
v3.1.4-xvm chgset 'Mon Nov 24 22:48:21 2008 -0800 15909:8ac8abf844b5'
SunOS Release 5.11 Version snv_101a 64-bit
Copyright 1983-2008 Sun Microsystems, Inc.  All rights reserved.
Use is subject to license terms.
Hostname: node2
Configuring devices.
/usr/cluster/bin/scdidadm:  Could not load DID instance list.
/usr/cluster/bin/scdidadm:  Cannot open
/etc/cluster/ccr/global/did_instances.
Booting as part of a cluster
name is non-existent for this module
for a list of valid names, use name '?'
NOTICE: CMM: Node node1 (nodeid = 1) with votecount = 1 added.
NOTICE: CMM: Node node2 (nodeid = 2) with votecount = 0 added.
NOTICE: clcomm: Adapter xnf2 constructed
NOTICE: clcomm: Adapter xnf1 constructed
NOTICE: CMM: Node node2: attempting to join cluster.
NOTICE: CMM: Node node1 (nodeid: 1, incarnation #: 1231582933) has
become reachable.
WARNING: xnf1: oversized packet (1518 bytes) dropped
NOTICE: clcomm: Path node2:xnf1 - node1:xnf1 online
NOTICE: clcomm: Path node2:xnf2 - node1:xnf2 online
WARNING: xnf1: oversized packet (1518 bytes) dropped
WARNING: xnf1: oversized packet (1518 bytes) dropped
WARNING: xnf2: oversized packet (1518 bytes) dropped
WARNING: xnf2: oversized packet (1518 bytes) dropped
WARNING: xnf2: oversized packet (1518 bytes) dropped


# uname -srvi
SunOS 5.11 snv_104 i86xpv

# dladm show-link
LINK        CLASS    MTU    STATE    OVER
bge0        phys     1500   unknown  --
e1000g0     phys     1500   up       --
vnic1       vnic     1500   unknown  e1000g0
vnic2       vnic     1500   unknown  e1000g0
vnic18      vnic     1500   unknown  e1000g0
vnic19      vnic     1500   unknown  e1000g0
vnic20      vnic     1500   unknown  e1000g0



-- 
Regards,
Piotr Jasiukajtis | estibi | SCA OS0072
http://estseg.blogspot.com

Reply via email to