I thought it was ?
# pmfadm -L
tags: ln0d3844app_rg,ln0d3844app_zone,0.mon
ln0d3844app_rg,ln0d3844app_zone,0.svc
# clrs unmonitor ln0d3844app_zone
# pmfadm -L
tags: ln0d3844app_rg,ln0d3844app_zone,0.svc
# zlogin ln0d3844app init 6
Jun 19 11:50:58 HOSTNAME Cluster.RGM.fed: [ID 605976 daemon.notice] SCSLM zone
<ln0d3844app> down
...... Wait for the zone to reboot - and login to check it is up.....
# clrs monitor ln0d3844app_zone
Jun 19 11:51:55 HOSTNAMECluster.RGM.rgmd: [ID 387232 daemon.notice] resource
ln0d3844app_zone monitor enabled.
Jun 19 11:52:56 HOSTNAME
SC[SUNW.gds:6,ln0d3844app_rg,ln0d3844app_zone,gds_probe]: [ID 965278
daemon.error] The probe has requested an immediate failover. Attempting to
failover this resource group subject to other property settings.
Jun 19 11:52:56 HOSTNAME Cluster.RGM.rgmd: [ID 784560 daemon.notice] resource
ln0d3844app_zone status on node HOSTNAME change to R_FM_FAULTED
..... And it fails over to the other node in the cluster
--
This message posted from opensolaris.org