I thought it was ? 

# pmfadm -L
        tags: ln0d3844app_rg,ln0d3844app_zone,0.mon 
ln0d3844app_rg,ln0d3844app_zone,0.svc 

# clrs unmonitor ln0d3844app_zone
# pmfadm -L
        tags: ln0d3844app_rg,ln0d3844app_zone,0.svc 

# zlogin ln0d3844app init 6

Jun 19 11:50:58 HOSTNAME Cluster.RGM.fed: [ID 605976 daemon.notice] SCSLM zone 
<ln0d3844app> down

...... Wait for the zone to reboot - and login to check it is up.....

# clrs monitor ln0d3844app_zone

Jun 19 11:51:55 HOSTNAMECluster.RGM.rgmd: [ID 387232 daemon.notice] resource 
ln0d3844app_zone monitor enabled.

Jun 19 11:52:56 HOSTNAME 
SC[SUNW.gds:6,ln0d3844app_rg,ln0d3844app_zone,gds_probe]: [ID 965278 
daemon.error] The probe has requested an immediate failover. Attempting to 
failover this resource group subject to other property settings.

Jun 19 11:52:56 HOSTNAME Cluster.RGM.rgmd: [ID 784560 daemon.notice] resource 
ln0d3844app_zone status on node HOSTNAME change to R_FM_FAULTED

..... And it fails over to the other node in the cluster
--

This message posted from opensolaris.org


Reply via email to