> On Wed, Dec 06, 2017 at 10:48:23PM +0000, Anthony Via wrote:
> > I am testing seamless reloads on HAProxy 1.8.0 using the master-worker
> > model and am running into the following when sending SIGUSR2 to the master
> > process

Sorry I misread, my explanation in the previous post is not correct for the
seamless reload (-x + expose-fd), but only for a "classic" reload.

During a seamless reload, the new process try to get the FDs of the listeners
using the unix socket.

Did you try the seamless reload using -x without the master-worker?

-- 
William Lallemand

Reply via email to