On Thu, Apr 11, 2019 at 02:32:28PM -0400, francis Lavalliere wrote:
> So just to be clear, there is only 1 service, using a Master -> Worker
> config.
> 
> The service is working since many hours (no doing any restart, simply
> modification of the config and executing the hot-reload command)...

Yes but that's also what I was suggesting, that maybe it's reloaded
twice very fast in parallel and that one of them fails and removes
the socket.

> I'll try to dig deeper on myside also when I got a chance, I was mostly
> wondering if anyone had that kind of issue (i know using sockets file isnt
> much people are using).

In fact yes, most people have this for the CLI ("stats socket") so it's
not at all something uncommon.

Willy