osx were not stable few days on travis.
s390x also.

I think to wait for few days and if it will not be repaired, we will mark
all those as "allowed failures" for good.

пн, 23 мар. 2020 г. в 13:43, Willy Tarreau <w...@1wt.eu>:

> Hi Ilya,
>
> I think this time I managed to fix the ABNS test. To make a long story
> short, it was by design extremely sensitive to the new process's startup
> time, which is increased with larger FD counts and/or less powerful VMs
> and/or noisy neighbors. This explains why it started to misbehave with
> the commit which relaxed the maxconn limitations. A starting process
> stealing a few ms of CPU from the old one could make its keep-alive
> timeout expire before it got a new request on a reused connection,
> resulting in an empty response as reported by the client.
>
> I'm going to issue dev5 now. s390x is currently down but all x86 ones
> build and run fine for now.
>
> Cheers,
> Willy
>

Reply via email to