Title: Message
Create entry '1'. Here is how it is distributed -
 
ONE: 1                                  DOMAIN: 5
  DEFAULT PROCESSING ID: training       INSTITUTION: SOFTWARE SERVICE
  DEFAULT NUMBER INCOMING FILERS: 1     DEFAULT NUMBER OUTGOING FILERS: 1
Note that the domain value is a broken pointer and the processing ID is training, etc.  You'll probably want to change these values.  Use option HL MAIN MENU, Site Parameter Edit.
 
Lloyd
----- Original Message -----
Sent: Thursday, November 18, 2004 1:23 PM
Subject: RE: [Hardhats-members] Can not view/edit HL COMMUNICATION SERVER PARAMETERS

Lloyd,
 
Thanks for the info, I did that ans when re-indexing the file it says taht it has no entries (you mentioned that it should have one)?
Any ideas?
 
 
 
Thanks
Tavo
 
 
 
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Lloyd Milligan
Sent: Thursday, November 18, 2004 1:04 PM
To: [EMAIL PROTECTED]
Subject: Re: [Hardhats-members] Can not view/edit HL COMMUNICATION SERVER PARAMETERS

Yes, missing ^HLCS(869.3,0) is definitely a problem.  The question is, how did it go missing, and is the entry also missing?  You could reset it -
 
    SET ^HLCS(869.3,0)="HL COMMUNICATION SERVER PARAMETERS^869.3"
 
and then re-index the file (which should have one entry).
 
Lloyd
----- Original Message -----
Sent: Thursday, November 18, 2004 11:47 AM
Subject: [Hardhats-members] Can not view/edit HL COMMUNICATION SERVER PARAMETERS

Hi,
I'm trying to set up VistA, and going throught the configuration document...
I'm trying to access the HL COMMUNICATION SERVER PARAMETERS but I can not.
Is ther any special privilages that I need to set before this...
I'm not getting any errors, when I type the following, after selecting HL COMMUNICATION SERVER PARAMETERS, it sends me back the the "Select OPTION:" instead of the "EDIT WHICJ FIELD: ALL//" prompt.

This is what I'm typing...
GTM> D P^DI
Select OPTION: ENTER OR EDIT FILE ENTRIES
Input to what File: <"last accessed file">//HL COMMUNICATION SERVER PARAMETERS <enter>



Select OPTION:

The same happens when selecting INQUIRE TO FILE ENTRIES... However, if I go under UTILITY FUNCTIONS and try most any options there, i get "Missing or incomplete global node ^HLCS(869.3,0)"

Is that the problem? Can I rebuild such a file? I'm totally lost...Any help/pointer would be appreciated.


Gustavo Vasconcelos
Software Developer
Stroudwater Technologies
207.347.8080 ext.222
http://www.stroudtech.com

Reply via email to