Select OPTION: 8  DATA DICTIONARY UTILITIES
Select DATA DICTIONARY UTILITY OPTION: LIST FILE ATTRIBUTES
 START WITH WHAT FILE: REMOTE PROCEDURE// RPC BROKER SITE PARAMETERS
                                          (1 entry)
      GO TO WHAT FILE: RPC BROKER SITE PARAMETERS//
      Select SUB-FILE:
Select LISTING FORMAT: STANDARD//
Start with field: FIRST//
DEVICE:   CONSOLE    Right Margin: 80//
STANDARD DATA DICTIONARY #8994.1 -- RPC BROKER SITE PARAMETERS FILE
                                                   OCT 10,[EMAIL 
PROTECTED]:52:50
PAGE 1
STORED IN ^XWB(8994.1,  (1 ENTRY)   SITE: Vista-Office EHR   UCI: EHR,EHR
(VERSI
ON 1.1)
 
DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
----------------------------------------------------------------------------
---
This file holds the site parameters for this installation of the RPC Broker.
It will have only one entry -- the domain name of the installation site.
             ^^^^^^^^^^^^^^



-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of David
Sommers
Sent: Monday, October 10, 2005 5:39 PM
To: [email protected]
Subject: RE: [Hardhats-members] Fileman - RPC not allowing new entry

No I haven't.  Is there something online that I can read up on or a
ROUTINE that I can dig into?

 
David Sommers, Architect  |  Dialog Medical

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
Gregory Woodhouse
Sent: Monday, October 10, 2005 5:11 PM
To: [email protected]
Subject: Re: [Hardhats-members] Fileman - RPC not allowing new entry


On Oct 10, 2005, at 2:04 PM, Nancy Anthracite wrote:

> David, try replacing the domain instead of making a new one - i.e.,  
> after
> choose the domain you have, and then after the //, put the new name.
>
> On Monday 10 October 2005 04:08 pm, David Sommers wrote:
> Anyone ever get this?
>
>
>
> Select RPC BROKER SITE PARAMETERS DOMAIN NAME: VISTA.DIALOGMEDICAL.COM
>
>   Are you adding 'VISTA.DIALOGMEDICAL.COM' as
>
>     a new RPC BROKER SITE PARAMETERS (the 2ND)? No// Y  (Yes) ??
>
>
>

Have you tried looking up the input transform? There are a lot of  
possibilities here: I've seen input transforms checking for "magic"  
variables, looking to see if you hold a key, checking system  
parameters, etc. Basically, it can do anything you can program.

===
Gregory Woodhouse
[EMAIL PROTECTED]

"Design quality doesn't ensure success, but design failure can ensure  
failure."

--Kent Beck




-------------------------------------------------------
This SF.Net email is sponsored by:
Power Architecture Resource Center: Free content, downloads,
discussions,
and more. http://solutions.newsforge.com/ibmarch.tmpl
_______________________________________________
Hardhats-members mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/hardhats-members


-------------------------------------------------------
This SF.Net email is sponsored by:
Power Architecture Resource Center: Free content, downloads, discussions,
and more. http://solutions.newsforge.com/ibmarch.tmpl
_______________________________________________
Hardhats-members mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/hardhats-members



-------------------------------------------------------
This SF.Net email is sponsored by:
Power Architecture Resource Center: Free content, downloads, discussions,
and more. http://solutions.newsforge.com/ibmarch.tmpl
_______________________________________________
Hardhats-members mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/hardhats-members

Reply via email to