The last two.
Matt.
From: Mahsa Alizade shalchy <[email protected]>
Reply-To: Mahsa Alizade shalchy <[email protected]> Date: Wednesday, October 1, 2014 at 9:59 AM To: Matt Glasser <[email protected]> Subject: Re: [HCP-Users] Rest fMRI pipeline Dear Matt
Thank you for the prompt answer.I have downloaded "Q1" data and within my data there are three kinds of rfmri data:
3T_rfMRI_REST_preproc
3T_rfMRI_REST_fix
3T_rfMRI_REST_fixextended
I would be more than grateful if you could tell me which one is considered as "FIX
cleaned data".
Best,
Mahsa
On Wednesday, October 1, 2014 6:13 PM, "Glasser, Matthew" <[email protected]> wrote:
The FIX cleaned data have a very gentle high pass filter that mainly removes linear trends, 24 motion parameters regressed, and noise ICA components (classified by FIX) regressed. The minimally preprocessed data do not have any of these.
Peace,
Matt.
From: Mahsa Alizade shalchy <[email protected]>
Reply-To: Mahsa Alizade shalchy <[email protected]> Date: Wednesday, October 1, 2014 at 7:23 AM To: Hcp-users <[email protected]> Subject: [HCP-Users] Rest fMRI pipeline Dear all
Hi
I searched the whole page of HCP but could not find any answers.
Could any one please tell me whether preprocessing steps for rest fmri data include "filtering, removing linear trend and regressing out nuisance" or not?
Many thanks in advance.
Best,
Mahsa
_________________________ ______________________
HCP-Users mailing list [email protected] http://lists.humanconnectome.org/mailman/listinfo/hcp-users The materials in this message are private and may contain Protected Healthcare Information or other information of a sensitive nature. If you are not the intended recipient, be advised that
any unauthorized use, disclosure, copying or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this email in error, please immediately notify the sender via telephone or return mail.
The materials in this message are private and may contain Protected Healthcare Information or other information of a sensitive nature. If you are not the intended recipient, be advised that any unauthorized use, disclosure, copying or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this email in error, please immediately notify the sender via telephone or return mail. _______________________________________________ |
- [HCP-Users] Rest fMRI pipeline Mahsa Alizade shalchy
- Re: [HCP-Users] Rest fMRI pipeline Glasser, Matthew
- Re: [HCP-Users] Rest fMRI pipeline Glasser, Matthew