Hi Matt,
? ? ?Thank you very much for your ?detailed response. All things become clear 
now. ??
Best regards,Xuhong Liao
发件人:?Glasser, Matthew发送时间:?2014-11-23?23:20收件人:?Xuhong Liao; hcp-users主题:?Re: 
About data processing




Unfortunately that is something that anyone using gradient echo EPI has to deal 
with. ?Because of inhomogeneity in the magnetic field, some areas spins decay 
faster than other areas resulting in loss of signal. ?This is not a correctable 
artifact unfortunately.
 ?



Peace,



Matt.





From: Xuhong Liao <[email protected]>

Date: Sunday, November 23, 2014 at 4:24 AM

To: hcp-users <[email protected]>

Cc: Matt Glasser <[email protected]>

Subject: Re: Re: About data processing










?Hi Matt,
? ?
? ? ? Thank you very much for your response.?



? ? ? As your post, several slices of rsfMRI data (left-right encoded, second 
session) are displayed for one subject (ID: 100307) as examples. Please see 
attached for more details. We can observe there the BOLD signals are missing in 
certain brain regions,
 such as superior orbital frontal cortex and bilateral inferior temporal gyrus. 
I hope above statement is clear, if not please contact with me.



? ? ? Thanks again!



? Best regards,
? Xuhong Liao



?



---------- 已转发邮件 ----------

From:?"Glasser, Matthew" <[email protected]>

To:?liaoxuhong <[email protected]>, hcp-users <[email protected]>

Cc:?

Date:?Fri, 21 Nov 2014 19:03:11 +0000

Subject:?Re: [HCP-Users] About data processing


Can you post a picture of what you are talking about?



Peace,



Matt.





From: liaoxuhong <[email protected]>

Date: Friday, November 14, 2014 at 8:36 PM

To: hcp-users <[email protected]>

Subject: [HCP-Users] About data processing






Hi:



? ??I'm currently working with minimally preprocessed multiband 
resting-state?fMRI
 data (preprocessing pipeline v2) for unrelated 40 subjects from HCP.?Recently, 
we found BOLD signals are missing in certain brain regions,
 such?as superior orbital frontal cortex and bilateral inferior temporal 
gyrus.?Furthermore,
 this phenomenon is common for? rsfMRI data of all subjects we?have downloaded, 
no matter RL or LR phase encoding. We are puzzled with the?signal
 missing in these areas, and hence are seeking for your assistance.



Can anyone tell us how to deal with this issue?


?
Thanks.





Regards
Xuhong Liao












?



The materials in this message are private and may contain Protected Healthcare 
Information or other information of a sensitive nature. If you are not the 
intended
 recipient, be advised that any unauthorized use, disclosure, copying or the 
taking of any action in reliance on the contents of this information is 
strictly prohibited. If you have received this email in error, please 
immediately notify the sender via telephone
 or return mail.




_______________________________________________
HCP-Users mailing list
[email protected]
http://lists.humanconnectome.org/mailman/listinfo/hcp-users

Reply via email to