Date: Friday, February 13, 2015 at 5:06 PM To: Matt Glasser <[email protected]> Cc: "[email protected]" <[email protected]> Subject: Re: [HCP-Users] Projecting Label into White Matter With some experimentation, I found that mri_label2vol tends to create worse volumes than recon-all's aparc2aseg regardless of the surface you use. I ended up getting good results by making a binarized mask from the segmented volume in the T1w folder, dilating
it, and multiplying by a binarized WM mask to constrain the dilation to WM.
JohnOn Fri, Feb 13, 2015 at 3:36 PM, John Plass
<[email protected]> wrote:
The materials in this message are private and may contain Protected Healthcare Information or other information of a sensitive nature. If you are not the intended recipient, be advised that any unauthorized use, disclosure, copying or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this email in error, please immediately notify the sender via telephone or return mail. _______________________________________________ |