We used a sigma of 200s for all tasks.  In practice if you clean the data I 
doubt it matters whether you do anything more than a linear detrend.

Peace,

Matt.

From: 
<[email protected]<mailto:[email protected]>>
 on behalf of David Hofmann 
<[email protected]<mailto:[email protected]>>
Date: Thursday, June 29, 2017 at 7:56 AM
To: hcp-users 
<[email protected]<mailto:[email protected]>>
Subject: [HCP-Users] How to choose high-pass filter cut-off period for the task 
data (block design)

Hi all,

I was wondering how to choose the high-pass filter cut-off period (in seconds) 
for the task data when the block onset files are used for the 1st level GLM 
(with spm12). As far as I understood the period should be around twice the 
period until a block repeats.

Based on the .txt onset files (reading out the block duration) I determined the 
following cut-off frequencies (in seconds), but I'm confused about what to 
choose for the Motor and the Working memory task:

Emotion: 72s (block length=18s -> 2*18*2)
Gambling: 112s (block length = 28s -> 2*28*2)
Language: 86s (block length math ~13s, block length story ~ 30s -> (13+30)*2)
Motor: ? (block length  = 12s, but there are several blocks, so not sure here)
Relational: 64s (block length = 16s -> 2*16*2)
Social: 92s (block length = 23s -> 2*23*2)
WM: ? (the same blocks don't repeat here, so not sure)


I'm using the already preprocessed volume data files (e.g. tfMRI_EMOTION_LR.nii 
from 100307_3T_tfMRI_EMOTION_preproc)

Any help appreciated!

greetings

David

_______________________________________________
HCP-Users mailing list
[email protected]<mailto:[email protected]>
http://lists.humanconnectome.org/mailman/listinfo/hcp-users

_______________________________________________
HCP-Users mailing list
[email protected]
http://lists.humanconnectome.org/mailman/listinfo/hcp-users

Reply via email to