https://issues.apache.org/jira/browse/HDFS-16689?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
ZanderXu updated HDFS-16689:
----------------------------
Description:
Standby NameNode crashes when transitioning to Active with a in-progress
tailer. And the error message like blew:
{code:java}
Caused by: java.lang.IllegalStateException: Cannot start writing at txid X when
there is a stream available for read: ByteStringEditLog[X, Y],
ByteStringEditLog[X, 0]
at
org.apache.hadoop.hdfs.server.namenode.FSEditLog.openForWrite(FSEditLog.java:344)
at
org.apache.hadoop.hdfs.server.namenode.FSEditLogAsync.openForWrite(FSEditLogAsync.java:113)
at
org.apache.hadoop.hdfs.server.namenode.FSNamesystem.startActiveServices(FSNamesystem.java:1423)
at
org.apache.hadoop.hdfs.server.namenode.NameNode$NameNodeHAContext.startActiveServices(NameNode.java:2132)
... 36 more
{code}
After tracing and found there is a critical bug in
*EditlogTailer#catchupDuringFailover()* when *DFS_HA_TAILEDITS_INPROGRESS_KEY*
is true. Because *catchupDuringFailover()* try to replay all missed edits from
JournalNodes with *onlyDurableTxns=true*. It may cannot replay any edits when
they are some abnormal JournalNodes.
Reproduce method, suppose:
- There are 2 namenode, namely NN0 and NN1, and the status of echo namenode is
Active, Standby respectively. And there are 3 JournalNodes, namely JN0, JN1 and
JN2.
- NN0 try to sync 3 edits to JNs with started txid 3, but only successfully
synced them to JN1 and JN3. And JN0 is abnormal, such as GC, bad network or
restarted.
- NN1's lastAppliedTxId is 2, and at the moment, we are trying failover active
from NN0 to NN1.
- NN1 only got two responses from JN0 and JN1 when it try to selecting
inputStreams with *fromTxnId=3* and *onlyDurableTxns=true*, and the count txid
of response is 0, 3 respectively. JN2 is abnormal, such as GC, bad network or
restarted.
- NN1 will cannot replay any Edits with *fromTxnId=3* from JournalNodes because
the *maxAllowedTxns* is 0.
So I think Standby NameNode should *catchupDuringFailover()* with
*onlyDurableTxns=false* , so that it can replay all missed edits from
JournalNode.
was:
Standby NameNode crashes when transitioning to Active with a in-progress
tailer. And the error message like blew:
{code:java}
Caused by: java.lang.IllegalStateException: Cannot start writing at txid X when
there is a stream available for read: ByteStringEditLog[X, Y],
ByteStringEditLog[X, 0]
at
org.apache.hadoop.hdfs.server.namenode.FSEditLog.openForWrite(FSEditLog.java:344)
at
org.apache.hadoop.hdfs.server.namenode.FSEditLogAsync.openForWrite(FSEditLogAsync.java:113)
at
org.apache.hadoop.hdfs.server.namenode.FSNamesystem.startActiveServices(FSNamesystem.java:1423)
at
org.apache.hadoop.hdfs.server.namenode.NameNode$NameNodeHAContext.startActiveServices(NameNode.java:2132)
... 36 more
{code}
After tracing and found there is a critical bug in
*EditlogTailer#catchupDuringFailover()* when *DFS_HA_TAILEDITS_INPROGRESS_KEY*
is true. Because *catchupDuringFailover()* try to replay all missed edits from
JournalNodes with *onlyDurableTxns=true*. It may cannot replay any edits when
they are some abnormal JournalNodes.
Reproduce method, suppose:
- There are 2 namenode, namely NN0 and NN1, and the status of echo namenode is
Active, Standby respectively. And there are 3 JournalNodes, namely JN0, JN1 and
JN2.
- NN0 try to sync 3 edits to JNs with started txid 3, but only successfully
synced them to JN1 and JN3. And JN0 is abnormal, such as GC, bad network or
restarted.
- NN1's lastAppliedTxId is 2, and at the moment, we are trying failover active
from NN0 to NN1.
- NN1 only got two responses from JN0 and JN1 when it try to selecting
inputStreams with *fromTxnId=3* and *onlyDurableTxns=true*, and the count txid
of response is 0, 3 respectively. JN2 is abnormal, such as GC, bad network or
restarted.
- NN1 will cannot replay any Edits with *fromTxnId=3* from JournalNodes because
the *maxAllowedTxns* is 0.
So I think Standby NameNode should *catchupDuringFailover()* with
*onlyDurableTxns=true* , so that it can replay all missed edits from
JournalNode.
> Standby NameNode crashes when transitioning to Active with in-progress tailer
> -----------------------------------------------------------------------------
>
> Key: HDFS-16689
> URL: https://issues.apache.org/jira/browse/HDFS-16689
> Project: Hadoop HDFS
> Issue Type: Bug
> Reporter: ZanderXu
> Assignee: ZanderXu
> Priority: Critical
> Labels: pull-request-available
> Time Spent: 10m
> Remaining Estimate: 0h
>
> Standby NameNode crashes when transitioning to Active with a in-progress
> tailer. And the error message like blew:
> {code:java}
> Caused by: java.lang.IllegalStateException: Cannot start writing at txid X
> when there is a stream available for read: ByteStringEditLog[X, Y],
> ByteStringEditLog[X, 0]
> at
> org.apache.hadoop.hdfs.server.namenode.FSEditLog.openForWrite(FSEditLog.java:344)
> at
> org.apache.hadoop.hdfs.server.namenode.FSEditLogAsync.openForWrite(FSEditLogAsync.java:113)
> at
> org.apache.hadoop.hdfs.server.namenode.FSNamesystem.startActiveServices(FSNamesystem.java:1423)
> at
> org.apache.hadoop.hdfs.server.namenode.NameNode$NameNodeHAContext.startActiveServices(NameNode.java:2132)
> ... 36 more
> {code}
> After tracing and found there is a critical bug in
> *EditlogTailer#catchupDuringFailover()* when
> *DFS_HA_TAILEDITS_INPROGRESS_KEY* is true. Because *catchupDuringFailover()*
> try to replay all missed edits from JournalNodes with *onlyDurableTxns=true*.
> It may cannot replay any edits when they are some abnormal JournalNodes.
> Reproduce method, suppose:
> - There are 2 namenode, namely NN0 and NN1, and the status of echo namenode
> is Active, Standby respectively. And there are 3 JournalNodes, namely JN0,
> JN1 and JN2.
> - NN0 try to sync 3 edits to JNs with started txid 3, but only successfully
> synced them to JN1 and JN3. And JN0 is abnormal, such as GC, bad network or
> restarted.
> - NN1's lastAppliedTxId is 2, and at the moment, we are trying failover
> active from NN0 to NN1.
> - NN1 only got two responses from JN0 and JN1 when it try to selecting
> inputStreams with *fromTxnId=3* and *onlyDurableTxns=true*, and the count
> txid of response is 0, 3 respectively. JN2 is abnormal, such as GC, bad
> network or restarted.
> - NN1 will cannot replay any Edits with *fromTxnId=3* from JournalNodes
> because the *maxAllowedTxns* is 0.
> So I think Standby NameNode should *catchupDuringFailover()* with
> *onlyDurableTxns=false* , so that it can replay all missed edits from
> JournalNode.
--
This message was sent by Atlassian Jira
(v8.20.10#820010)
---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]