Todd Lipcon created HDFS-3357:
---------------------------------
Summary: DataXceiver reads from client socket with incorrect/no
timeout
Key: HDFS-3357
URL: https://issues.apache.org/jira/browse/HDFS-3357
Project: Hadoop HDFS
Issue Type: Bug
Components: data-node
Affects Versions: 1.0.2, 2.0.0
Reporter: Todd Lipcon
Assignee: Todd Lipcon
Priority: Critical
In DataXceiver, we currently use Socket.setSoTimeout to try to manage the read
timeout when switching between reading the initial opCode, reading a keepalive
opcode, and reading the status after a successfully sent block. However, since
all of these reads use the same underlying DataInputStream, the change to the
socket timeout isn't respected. Thus, they all occur with whatever timeout is
set on the socket at the time of DataXceiver construction. In practice this
turns out to be 0, which can cause infinitely hung xceivers.
--