On Wednesday 02 December 2009, Rubén Gómez Antolí wrote: > I think that I miss something using measure command. > I follow Gnucap's wiki manual: > http://gnucap.org/dokuwiki/doku.php?id=gnucap:manual:commands:measure > > I want to get the RMS value of a signal in a circuit, for it > I do: > > gnucap> probe tran i(RMEASA) > gnucap> tran 0 10ms 50us uic > #Time i(RMEASA) > 0. 0. > 50.u 0.0020859 > 100.u 0.0033786 > 150.u 0.0041567 > 200.u 0.0046241 > 250.u 0.0049039 > 300.u 0.0050698 > 350.u 0.0051667 > > (...) > > 0.0099 -0.0053322 > 0.00995 -0.0053357 > 0.01 -0.0053384 > gnucap> measure eficaz = rms(probe="i(RMEASA)") > no match: i(RMEASA)
Thanks for the comments .. the documentation needs improvement. I have made some changes to the documentation to try to clarify this. Look again. Hopefully it is better now. http://gnucap.org/dokuwiki/doku.php?id=gnucap:manual:commands:measure _______________________________________________ Help-gnucap mailing list [email protected] http://lists.gnu.org/mailman/listinfo/help-gnucap