On Dec 2, 2007, at 1:42 PM, Ben Hood wrote:


We did just change that.

When is this likely to be published? Is there going to be an announcement?


I'm not sure. There are a few other changes we need to add (adding Byte, Short, Character.) Probably in 1-2 months.


The production should be

O, string (type), int (# of fields), field name 1, field name 2, ...

So the x0b is the string short code, not the byte value x0b (even though they're the same code).

So a type with length 48 would use O S x00 x30 ...

OK, that's fine. By that token would the above example use

O x0b example.Car

or

O S x00 x0b example.Car

to use the compact string encoding?

Yes, thanks for catching that.

-- Scott


-- Ben

-- Scott




O, length(Type), number of fields, field name 1, field name 1

indicating that the production

t b16 b8 typestring

is actually
int typestring.

This does seem to be a more compact representation, but it differs from the spec. Which one is right?

Thx,

Ben