A question that came up regarding negative reagent controls for IHC...currently 
using Ventana i-View.  Our regular negative control goes through the standard 
antigen retrieval steps, like 99% of our antibodies.  However there are a small 
number of antibodies that require enzyme as well (Protease 1).  I've seen a 
number of suggestions regarding this for the negative reagent control...some 
say use an additional negative control protocol that includes the protease, 
some say to use a single negative control protocol and just include the 
harshest cell conditioning that any of your protocols use (so basically use the 
cell conditioning + protease negative control for all antibodies)...i-View is 
not polymer-based so we need to continue using negative controls.  Any thoughts 
or advice?