https://issues.apache.org/jira/browse/HIVE-635?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Carl Steinbach updated HIVE-635:
--------------------------------
Fix Version/s: 0.4.0
Affects Version/s: (was: 0.3.1)
> UnionOperator fails when different inputs have different ObjectInspector (but
> the same TypeInfo)
> ------------------------------------------------------------------------------------------------
>
> Key: HIVE-635
> URL: https://issues.apache.org/jira/browse/HIVE-635
> Project: Hadoop Hive
> Issue Type: Bug
> Affects Versions: 0.3.0
> Reporter: Zheng Shao
> Assignee: Zheng Shao
> Fix For: 0.4.0
>
> Attachments: HIVE-635.1.patch, HIVE-635.3.patch, HIVE-635.4.patch
>
>
> The current UnionOperator code assumes the ObjectInspectors from all parents
> are the same.
> But in reality, they can be different, and UnionOperator needs to do
> conversion if necessary.
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.