Hello,

> On Mar 25, 2015, at 12:37 PM, JF Tremblay 
> <jean-francois.tremb...@viagenie.ca> wrote:
> 
> 
>> On Mar 25, 2015, at 11:26 AM, Timothy Winters <twint...@iol.unh.edu> wrote:
>> 
>> Hi,
>>      For the IPv6 Ready/UNH-IOL testing that we have done, both an 
>> Interoperability and Conformance, there is a test  makes sure a Router 
>> supports getting multiple IA_PDs for Prefix Change.
> 
> Thanks Tim. 
> 
> Two questions: 
> 1. Can you share any data on how often this requirement was met or not? (like 
> a % of tested routers)
> 2. Do you also test for L-13? And is that one usually met?
Currently we have about 15 to 20 implementations at the IOL that are trying to 
meet the 7084 Requirements, including L-13.   Most routers address issues when 
they are made aware of the problem.
> 
> JF
> 
> 
> 
> 
> 