Hi Greg,

That causes the query to go to the top-level and block there (it appears common 
for send times to be more than 30 seconds).  :/

Brian

Sent from my iPhone

> On Mar 10, 2017, at 5:01 PM, Greg Thain <[email protected]> wrote:
> 
>> On 03/10/2017 03:42 PM, Brian Bockelman wrote:
>> Hi folks,
>> 
>> Any wild ideas of how I could grease the top-level collector to at least 
>> survive the weekend?
>> 
>> We have a lot of cores in the pool currently (consistently over 200k), 
>> causing the OOM killer to fire about once a minute.
> 
> Is turning down COLLECTOR_QUERY_WORKERS a possibility?
> -greg
> _______________________________________________
> HTCondor-devel mailing list
> [email protected]
> https://lists.cs.wisc.edu/mailman/listinfo/htcondor-devel

_______________________________________________
HTCondor-devel mailing list
[email protected]
https://lists.cs.wisc.edu/mailman/listinfo/htcondor-devel

Reply via email to