Just a side-note: > On 03 Sep 2015, at 09:03, Terry Duell <[email protected]> wrote: > > I resample the images to twice the pixel resolution, then align these to a > specified accuracy using a DFT method (see Manuel Guizar-Sicairos, Samuel T. > Thurman, and James R. Fienup, "Efficient subpixel image registration > algorithms," Opt. Lett. 33, 156-158 (2008).), I am currently using 1/2 pixel > accuracy. I then average the 4 images.
I’ll tell Manuel that his algorithm is used “in the wild”, he works at the same institute as I do: http://www.psi.ch/media/from-inside-an-eggshell Greetings, Habi -- A list of frequently asked questions is available at: http://wiki.panotools.org/Hugin_FAQ --- You received this message because you are subscribed to the Google Groups "hugin and other free panoramic software" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/hugin-ptx/85FB8077-2071-40DB-AAED-3BD1C7D3C04D%40gmail.com. For more options, visit https://groups.google.com/d/optout.