Hallo Daniel, Am Mittwoch, 16. Januar 2019 20:06:40 UTC+1 schrieb [email protected]: > > from a tcsh under cygwin. The command produced a single output file > (Aligned0000.tif). > I expected one output file for each input file. >
Align_image_stack has problem with these images. There are only some very small areas which are in focus and the out-of-focus area have nearly no structure. So the found control points are of bad quality. As a consequence after control point pruning the reference image has no control points. When you now optimize with hfov (-m switch) the hfov of the images is optimized to zero (but the hfov of the reference is not optimized and stays high). The zero hfov results now in the empty output. I fear these images are not good suited for align_image_stack. (For debug you can output a pto file (-p switch) and inspect the pto file in Hugin.) Maybe playing with the parameters -t and/or --corr can help in this case. But don't expect wonders. Thomas -- A list of frequently asked questions is available at: http://wiki.panotools.org/Hugin_FAQ --- You received this message because you are subscribed to the Google Groups "hugin and other free panoramic software" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/hugin-ptx/4a4545b6-31df-4678-b66e-daf6f34e8eaa%40googlegroups.com. For more options, visit https://groups.google.com/d/optout.