Hi,

Am Freitag, 15. März 2019 18:40:56 UTC+1 schrieb Rainer Woitok:
>
> Question 1: Am I correct in assuming that when a new lens is assigned to 
> "i1", that is, the second image, the first and second image have differ- 
> ent lenses (whatever that means)? 
>
Yes, that' correct. 

>
> Question 2: What if I stitch three scans or more?  Do I have to specify 
>
>    pto_lensstack --new-lens i1,i2,... -o ... ? 
>
> Any pointers to the concepts  behind the terms  "lens" and "stack" would 
> be heartily appreciated. 
>
Normally all images with the same lens share the same lens parameters 
(field of view, distortion parameter,..). This you would expect when you 
shoot all images with the same lens.
This also reduces the parameters for the optimizer and makes the 
optimization more stable. 
For scanned images this lens concept is not so good. So you would like to 
optimize the field of view for each individual image. This can be achieved 
by assigning each image an own lens or by unlink the fov parameter of this 
lens (pto_var --unlink v0).

For stacks this is analog done for the image positions.

PS: Current Hugin version contains also an user-defined assistant for 
scanned images.

-- 
A list of frequently asked questions is available at: 
http://wiki.panotools.org/Hugin_FAQ
--- 
You received this message because you are subscribed to the Google Groups 
"hugin and other free panoramic software" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/hugin-ptx/bd8adde9-52af-4ead-bdc6-11bf938d47dc%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to